Is your building a heat network?

If one heat source supplies heating or hot water to two or more flats in one building, it very probably is. These are the exemptions, and how to tell whether one applies.

Last checked against Ofgem’s guidance on . General information, not legal advice.

01The basic test

A heat network moves heat, through water or another fluid, from a shared source to more than one place. Ofgem regulates two kinds:

  • A communal heat network supplies heating, cooling or hot water to a single building divided into separate premises, such as a block of flats with one boiler in the plant room.
  • A district heat network supplies two or more buildings, such as an estate heated from one energy centre.

Flats that each have their own gas boiler or their own heat pump are not on a heat network. Neither is a building where only the landlord’s common parts are heated.

A block of flats where one shared boiler heats every flat Several flats Separate homes, one building Shared pipework Heat or hot water to each flat One heat source Usually a boiler in the plant room A communal heat network
  1. Several flats. Separate homes, one building.
  2. Shared pipework. Heat or hot water to each flat.
  3. One heat source. Usually a boiler in the plant room.

02The exemptions

You do not apply for an exemption. If one of these fits, the rules simply do not apply to that network:

  • A single house in multiple occupation where residents share a kitchen or bathroom, as defined in section 254 of the Housing Act 2004.
  • A single converted building supplied by one heat source of 45 kW or less, about the size of a large domestic boiler.
  • A building with shared facilities that is not divided into separate homes, such as a care home.
  • A communal network that heats or cools only through air conditioning and supplies no hot water.
  • A third party that only produces waste heat and does not operate or supply the network.

03Converted blocks and the 45 kW rule

A house or older building converted into self-contained flats, known in housing law as a section 257 HMO, is not covered by the shared-facilities exemption. If its flats share a heating system, it may be a regulated heat network.

The exception is a converted building supplied by no more than one source appliance with a thermal capacity of 45 kW or less. Many small Victorian conversions with one domestic-sized boiler fall into it. Check the boiler’s rated output on its data plate or in the service records. Two boilers, or one larger than 45 kW, means the exemption does not apply.

04How residents pay does not decide it

Heat recovered through the service charge or the rent is still heat supplied over a network. Ofgem’s consumer protection guidance deals specifically with networks that recover heat costs through a service charge, which tells you they are regulated too.

Residents not receiving a separate heat bill is not an exemption.

05If you are still unsure

The scope check asks six plain-English questions about the heating, the building and who runs it, and gives a conservative answer on screen. No details are needed.

Ofgem’s who should register (opens in a new tab) page is the authoritative source, and its heat networks team will answer questions directly. Where the lease or a management agreement decides the answer, ask a solicitor.

Read next

The full guide to heat network regulation

Not sure if your block is in scope?

Run the scope check